Abstract
In this work, treatment of synthetic fluoride-containing solutions by electrocoagulation method using aluminium electrodes has been studied. Electrocoagulation was investigated for applied potential (10-30 V), electrolysis time and supporting electrolyte (NaCl) concentration (0-100 mg/L). The results showed that with increasing applied potential and electrolysis time, the Al3+ dosage increases, and thereby favouring the fluoride ions removal. It was also observed that defluoridation is dependant on the concentration of supporting electrolyte. Finally, X-ray diffraction, scanning electron microscopy, energy dispersive spectroscopy of X-rays and Fourier transform infrared spectroscopy were used to characterize the solid products formed by aluminium electrodes during the EC process.
Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety
Authors
, , , , , ,