Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
582606 | Journal of Hazardous Materials | 2009 | 9 Pages |
Abstract
This study focuses on the atmospheric dry deposition flux of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the vicinity of the two municipal solid waste incinerators (MSWIs) located in southern Taiwan. PCDD/Fs in ambient air were taken and analyzed for seventeen 2,3,7,8-substituted PCDD/Fs during November 2004 and July 2005. Results show that the mean concentrations of PCDD/Fs in the ambient air near MSWI-GS and MSWI-RW were 0.090 and 0.097Â pg I-TEQ/Nm3, respectively. Dry deposition fluxes of total PCDD/Fs were 18.0 and 23.5Â pg I-TEQ/(m2Â d) in the ambient air near MSWI-GS and MSWI-RW, respectively, which were considerably higher than that measured in Guangzhou, China. Annual dry deposition fluxes of total PCDD/Fs in the ambient air near MSWI-GS and MSWI-RW were 189 and 217Â ng/(m2Â year), respectively, which were also much higher than dry deposition of total PCDD/Fs to the Atlantic Ocean. The results of the present study strongly suggest that exposure to PCDD/Fs in this area should be reduced. In addition, parametric sensitivity shows that dry deposition flux of PCDD/Fs is most sensitive to dry deposition velocity of the particle-phase, followed by air temperature and concentration of total suspended particulate but least sensitive to dry deposition velocity of the gas-phase.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Chemical Health and Safety
Authors
Yee-Lin Wu, Long-Full Lin, Lien-Te Hsieh, Lin-Chi Wang, Guo-Ping Chang-Chien,