Article ID Journal Published Year Pages File Type
582783 Journal of Hazardous Materials 2008 8 Pages PDF
Abstract
Although many researches focused on the polychlorinated dibenzo-p-dioxins/dibenzofuran (PCDD/F) emissions from stack, in the bottom ash and in the surrounding environment, researches focused on PCDD/F mass distributions in the whole incineration plant have seldom been addressed. This study determined PCDD/F emissions in the whole plant. A high-resolution gas chromatograph/high-resolution mass spectrometer was utilized for analyzing 17 PCDD/F species. Experimental results displayed that PCDD/Fs were formed during fly ash from super heater (SH), economizer (EC), semi-dryer absorber (SDA) and fabric filter (FF) was transferred to fly ash pit. Mass distribution ratios of PCDD/Fs in g I-TEQ (Toxicity Equivalency Quantity) per week from stack, SH, EC, SDA, FF, generation and bottom residue (BR) in start-up operations were 14.6%, 0.1%, 8.3%, 1.0%, 41.7%, 33.4% and 0.9%, respectively. Above results indicated that main PCDD/F source in the MSWI was from fly ash. However, the fly ash is easily controlled and PCDD/F emitted from stack flue gases will be difficult to be handled. Therefore, we should pay more attention on PCDD/F emission from flue gases especially from start-up procedure. Besides, fly ash should be controlled by sodium hypophosphite before being landfilled. MSWI did require further detoxification treatments for the solid residues and flue gases.
Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety