Abstract
This paper presents the development of an on-line pre-concentration system to determine cadmium(II) in aqueous samples. The analyte was trapped in a mini-column filled with Al2O3 in the form of macro-spheres obtained by the mixture of Al(NO3)3·9H2Oaq and chitosan dissolved in acetic acid. The mixture was dropped into an NH4OH aqueous solution under rigorous agitation using a peristaltic pump, the macro-spheres were separated from alkaline solution and dried, and finally were submitted to thermal treatment. The pre-concentration system was linear between 1.0 and 100 μg Lâ1, with a linearity of 0.999, sensitivity of 3.58 Ã 10â3 L μgâ1 and enrichment factor of 21.9. The limits of detection and quantification were 0.08 μg Lâ1 and 0.28 μg Lâ1, respectively. The repeatability was between 2.6 and 5.9%. Recovery tests were carried out with a real aqueous sample.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Chemical Health and Safety
Authors
Ãrica Silva Souza, Amarildo Otavio Martins, Humberto Vieira Fajardo, Luiz Fernando Dias Probst, Eduardo Carasek,