Using a multi-temperature artificial ageing testing apparatus and a standard method of determining the effective centralite/stabilizer content, the effective centralite/stabilizer content for varying time period in propellants heated at 95 °C, 90 °C, 85 °C, 75 °C and 65 °C was measured. Bethelot's equation and Semenov's equation in the temperature range of 65-95 °C for 81 propellants were established. The safe storage life at 30 °C, kinetic parameters [the apparent activation energy (E) and the pre-exponential constant (A)] and isolife temperatures obtained from the established equations and the activation energy (Eα=0.5) obtained by integral isoconversional non-linear method for 81 propellants: single-base gun propellants (DF-01-DF-16), double-base gun propellants (SF-01-SF-13), tri-base gun propellants (SG-01-SG-02), nitramine gun propellants (GSF-01-GSF-18), double-base propellants (ST-01-ST-13), and composite modified double-base propellants (GST-01-GST-19), were given. Information was obtained on the effective centralite/stabilizer consumption reaction and the kinetic compensation effect.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Chemical Health and Safety
Authors
Zhao Fengqi, Heng Shuyun, Hu Rongzu, Gao Hongxu, Han Fang,