Article ID Journal Published Year Pages File Type
5864047 Journal of Manipulative and Physiological Therapeutics 2013 7 Pages PDF
Abstract

ObjectiveIt is believed that systematic modulation of spinal manipulative therapy (SMT) parameters should yield varying levels of physiological responses and eventually a range of clinical responses. However, investigation of SMT dose-physiological response relationship is recent and has mostly been conducted using animal or cadaveric models. The main objective of the present study is to investigate SMT dose-physiological response relation in humans by determining how different levels of force can modify electromyographic (EMG) responses to spinal manipulation.MethodsTwenty-six participants were subjected to 2 trials of 4 different SMT force-time profiles using a servo-controlled linear actuator motor. Normalized EMG activity of paraspinal muscles (left and right muscles at level T6 and T8) was recorded during and after SMT, and EMG values were compared across the varying levels of force.ResultsIncreasing the level of force yielded an increase in paraspinal muscle EMG activity during the thrust phase of SMT but also in the two 250-millisecond time windows after the spinal manipulation impulse. These muscle activations quickly attenuated (500 milliseconds after spinal manipulation impulse).ConclusionThe study confirmed the presence of a local paraspinal EMG response after SMT and highlighted the linear relationship between the SMT peak force and paraspinal muscle activation.

Related Topics
Health Sciences Medicine and Dentistry Complementary and Alternative Medicine
Authors
, , , , , ,