Article ID Journal Published Year Pages File Type
586962 Journal of Loss Prevention in the Process Industries 2013 9 Pages PDF
Abstract

This work investigates the ignition of tetrafluoroethylene induced by the adiabatic compression that can arise by activating a high speed valve separating two portions of a pipeline with a high pressure difference. In the tests performed the high pressure zone contained tetrafluoroethylene at pressures between 15 and 30 bar. For the low pressure zone, experiments with nitrogen, air and tetrafluoroethylene were carried out. The pressure range in the low pressure zone was comprised between 0.05 and 1 bar. The pipe diameters analyzed were 15 and 20 mm. For the analyzed geometries, special conditions were required in order to reach reproducible ignitions, namely air at temperatures of at least 105 °C had to be present in the compression pipe. Furthermore, a minimum length of the compression pipe had to be used. The current work describes the experimental setup employed for the tests and discusses the achieved results. Numerical simulations were performed in order to clarify unexpected findings.

► The ignition of tetrafluoroethylene induced by adiabatic compression was investigated. ► The pipe diameters analyzed were 15 and 20 mm. ► Reproducible ignitions were achieved only for specific setup configurations and initial conditions. ►Tests with no ignition showed much lower temperatures than the ones predicted by the shock wave theory. ► Numerical simulations were performed in order to clarify these unexpected findings.

Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety
Authors
, , , , ,