Article ID Journal Published Year Pages File Type
587233 Journal of Loss Prevention in the Process Industries 2007 9 Pages PDF
Abstract

A simple n-compartment mathematical model is developed to study the effectiveness of fluid curtains and transient behaviour in mitigating the effects of an accidental chlorine release. The model is obtained considering chemical and physical absorption effectiveness of the toxic cloud by a reacting liquid curtain. The characteristics of the curtain and the evolution were deeply studied by means of replicated wind tunnel experimental runs, according to different operating parameters. An analytical solution of the model is presented. A fairly good agreement was verified between the model predictions and the original experimental results here presented.

Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety
Authors
, , ,