•A C7F14 permeation plug release vessel (PPRV) was developed.•Thirty-six PPRVs with varying attributes were monitored.•An equation for calculating release rate was derived.•Detailed instructions for replicating the PPRV are provided.•The PPRV was simple to construct and to customize.
Perfluoromethylcyclohexane (PMCH) is a member of the perfluorocarbon tracer (PFT) group of compounds. PMCH has been widely used in various tracer gas studies to characterize ventilation systems, atmospheric transport patterns, and pollution distribution schemes. PMCH exists as a volatile liquid at room temperature and pressure, a characteristic that prevents PMCH from being deployed using traditional means. This paper presents a design for a permeation plug release vessel (PPRV) for PMCH. The PPRV is designed to passively deploy PMCH vapor at constant rate as a function of temperature and plug thickness for quantitative tracer gas studies. Details regarding the development process and the release rate analysis are included.
Graphical abstractFigure optionsDownload full-size imageDownload high-quality image (98 K)Download as PowerPoint slide