Abstract

This paper presents a computational fluid dynamics (CFD) model of the evaporating liquid cascade produced in a large hydrocarbon storage tank overfilling incident. The model is first validated against the results of a unique series of full-scale experiments, in which liquid hexane was released from a 10 m high tower. Comparisons are presented for the temperature of both the liquid and vapour in the cascade, and the temperature of the vapour current. The validated model is then used to investigate the effects of different tank bund configurations, and the influence of an accumulating vapour layer on the vapour production process.

► A CFD model for predicting vapour production from flammable liquid cascades is developed. ► The model is validated against a unique series of large scale experiments. ► Different cascade configurations beyond the experimental range are investigated.

Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety
Authors
, , , ,