Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6052435 | International Journal of Oral and Maxillofacial Surgery | 2014 | 6 Pages |
Abstract
The surgical treatment of mandibular condyle fractures currently offers several possibilities for stable internal fixation. In this study, a finite element model evaluation was performed of three different methods for osteosynthesis of low subcondylar fractures: (1) two four-hole straight plates, (2) one seven-hole lambda plate, and (3) one four-hole trapezoidal plate. The finite element model evaluation considered a load applied to the first molar on the contralateral side to the fracture. Results showed that, although the three methods are capable of withstanding functional loading, the lambda plate displayed a more homogeneous stress distribution for both osteosynthesis material and bone and may be a better method when single-plate fixation is the option.
Related Topics
Health Sciences
Medicine and Dentistry
Dentistry, Oral Surgery and Medicine
Authors
G.P. de Jesus, L.G. Vaz, M.F.R. Gabrielli, L.A. Passeri, T. V. Oliveira, P.Y. Noritomi, P. Jürgens,