Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6113873 | Transfusion and Apheresis Science | 2015 | 8 Pages |
Abstract
How to choose suitable serologic method for assessment of the actual stages of ABO chimera is more important to establish transfusion strategy for patients post-ABO incompatible hematopoietic stem cell transplantation. We reported ABO phenotypes of a patient post-ABO minor incompatible hematopoietic stem cell transplantation from 1+ weak agglutination by tube method was obviously reaffirmed to mixed fields with 4+ positive reaction by micro gel column card. Hence, blood bank technologists must continually work together with hematologist to establish appropriate transfusion strategy, and micro gel column technique can be more appropriate for detecting mixed fields during the whole period of transplantation.
Related Topics
Health Sciences
Medicine and Dentistry
Hematology
Authors
Min-Fang Li, Feng Liu, Min Zhang,