Abstract
Induction motors vibrations, caused by bearing defects, result in the modulation of the stator current. In this research, a method based on Park's vector approach for bearing fault detection using three-phase stator current analysis is presented. In order to evaluate the ability of the proposed method several experiments are performed, and sets of data are gathered before and after using defective bearings. Both localized and distributed defects are evaluated using this method. The experimental results from our study suggest that the proposed method provides a powerful and general approach to incipient fault detection.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Colloid and Surface Chemistry
Authors
Jafar Zarei, Javad Poshtan,