Article ID Journal Published Year Pages File Type
6190801 Clinical Radiology 2015 6 Pages PDF
Abstract

•ADC values of suspicious prostate regions were normalized to benign tissue (nADC).•Two independent radiologists, blinded to pathology, performed the analyses.•Assessments were performed for both tumor detection and grade in both the PZ and TZ.•ADC overall outperformed nADC for both observers for the various endpoints.•Caution is warranted when applying normalization of ADC values in clinical practice.

AimTo evaluate the performance of normalised apparent diffusion coefficient (ADC) values for prostate cancer assessment when performed by independent observers blinded to histopathology findings.Materials and methodsFifty-eight patients undergoing 3 T phased-array coil magnetic resonance imaging (MRI) including diffusion-weighted imaging (DWI; maximal b-value 1000 s/mm2) before prostatectomy were included. Two radiologists independently evaluated the images, unaware of the histopathology findings. Regions of interest (ROIs) were drawn within areas showing visually low ADC within the peripheral zone (PZ) and transition zone (TZ) bilaterally. ROIs were also placed within regions in both lobes not suspicious for tumour, allowing computation of normalised ADC (nADC) ratios between suspicious and non-suspicious regions. The diagnostic performance of ADC and nADC were compared.ResultsFor PZ tumour detection, ADC achieved significantly higher area under the receiver operating characteristic curve (AUC; p=0.026) and specificity (p=0.021) than nADC for reader 1, and significantly higher AUC (p=0.025) than nADC for reader 2. For TZ tumour detection, nADC achieved significantly higher specificity (p=0.003) and accuracy (p=0.004) than ADC for reader 2. For PZ Gleason score >3+3 tumour detection, ADC achieved significantly higher AUC (p=0.003) and specificity (p=0.005) than nADC for reader 1, and significantly higher AUC (p=0.023) than nADC for reader 2. For TZ Gleason score >3+3 tumour detection, ADC achieved significantly higher specificity (p=0.019) than nADC for reader 1.ConclusionIn contrast to prior studies performing unblinded evaluations, ADC was observed to outperform nADC overall for two independent observers blinded to the histopathology findings. Therefore, although strategies to improve the utility of ADC measurements in prostate cancer assessment merit continued investigation, caution is warranted when applying normalisation to improve diagnostic performance in clinical practice.

Related Topics
Health Sciences Medicine and Dentistry Oncology
Authors
, , , , , ,