Article ID Journal Published Year Pages File Type
620302 Wear 2006 10 Pages PDF
Abstract

Unacceptable levels of surface degradation of metal containment walls and heat exchanger tubing by a combined erosion-corrosion (E-C) mechanism have been experienced in some boilers. The recent use of coatings to protect the heat exchanger tubes of fluidized bed combustor from E-C problems has been suggested by many authors. The laser remelting of the surface coating is suggested as a promising technique to improve its physical properties.Aim of the present investigation is to evaluate the erosion-corrosion (E-C) behaviour of plasma as sprayed and laser remelted Stellite-6 (St-6) coatings on boiler tube steels in the actual coal fired boiler environment. The cyclic experimental studies were performed in the platen superheater zone of a coal fired boiler where the temperature was around 755 °C and the study was carried out upto 10 cycles each of 100 h duration followed by 1 h cooling at ambient temperature. Coated steels were found to possess higher resistance to E-C than the uncoated steels. The highest degradation resistance has been indicated by the T11 steel coated and subsequently laser remelted.

Related Topics
Physical Sciences and Engineering Chemical Engineering Colloid and Surface Chemistry
Authors
, ,