Article ID Journal Published Year Pages File Type
6204813 Clinical Biomechanics 2013 6 Pages PDF
Abstract

BackgroundReliable periprosthetic fracture treatment needs detailed knowledge on the mechanical behavior of the fixation components used. The holding capacity of three conventional fixation components for periprosthetic fracture treatment was systematically investigated under different loading directions.MethodsLocking compression plates were fixed to a 7 cm long part of diaphyseal fresh frozen human femur with either a single 1.7 mm cerclage cable, a 5.0 mm monocortical or a bicortical locking screw (n = 5 per group). Constructs were loaded in lateral, torsional and axial direction with respect to the bone axis in a load-to-failure test. Corresponding stress distribution around the screw holes was analyzed by finite element modeling.FindingsBoth screw fixations revealed significantly higher stiffness and ultimate strength in axial compression and torsion compared to the cerclage (all P < 0.01). Ultimate strength in lateral loading and torsion was significantly higher for bicortical screws (mean 3968 N SD 657; mean 28.8 Nm SD 5.9) compared to monocortical screws (mean 2748 N SD 585; mean 14.4 Nm SD 5.7 Nm) and cerclages (mean 3001 N SD 252; mean 3.2 Nm SD 2.0) (P ≤ 0.04). Stress distribution around the screw hole varied according to the screw type and load direction.InterpretationFixation components may be combined according to their individual advantages to achieve an optimal periprosthetic fracture fixation.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , ,