Article ID Journal Published Year Pages File Type
6207721 Gait & Posture 2012 5 Pages PDF
Abstract

To measure the scapulohumeral rhythm (SHR) in outpatient settings, the motion analysis protocol named ISEO (INAIL Shoulder and Elbow Outpatient protocol) was developed, based on inertial and magnetic sensors. To complete the sensor-to-segment calibration, ISEO requires the involvement of an operator for sensor placement and for positioning the patient's arm in a predefined posture. Since this can affect the measure, this study aimed at quantifying ISEO intra- and inter-operator agreement. Forty subjects were considered, together with two operators, A and B. Three measurement sessions were completed for each subject: two by A and one by B. In each session, the humerus and scapula rotations were measured during sagittal and scapular plane elevation movements. ISEO intra- and inter-operator agreement were assessed by computing, between sessions, the: (1) similarity of the scapulohumeral patterns through the Coefficient of Multiple Correlation (CMC2), both considering and excluding the difference of the initial value of the scapula rotations between two sessions (inter-session offset); (2) 95% Smallest Detectable Difference (SDD95) in scapula range of motion.Results for CMC2 showed that the intra- and inter-operator agreement is acceptable (median ≥ 0.85, lower-whisker  ≥ 0.75) for most of the scapula rotations, independently from the movement and the inter-session offset. The only exception is the agreement for scapula protraction-retraction and for scapula medio-lateral rotation during abduction (inter-operator), which is acceptable only if the inter-session offset is removed. SDD95 values ranged from 4.4° to 8.6° for the inter-operator and between 4.9° and 8.5° for the intra-operator agreement.In conclusion, ISEO presents a high intra- and inter-operator agreement, particularly with the scapula inter-session offset removed.

► We developed a motion analysis protocol named ISEO for the ambulatory measure of the scapulohumeral rhythm. ► We assessed ISEO intra and inter-operator agreement involving 2 operators and 40 subjects. ► We quantified the similarity of scapulohumeral patterns and the smallest detectable difference in scapula range of motion. ► The similarity was acceptable for most of the scapula rotations. ► The smallest detectable difference ranged from 4.4° to 8.6°.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , , ,