Article ID Journal Published Year Pages File Type
6208964 The Journal of Arthroplasty 2015 5 Pages PDF
Abstract

To evaluate the mid-term effects of different materials and coatings used for femoral components, we prospectively performed 21 one-stage bilateral total hip arthroplasties using 2 anatomical stems which have identical geometries, randomized to side. One stem was made of Ti6Al4V alloy and had a hydroxyapatite coating on grit-blasted surface proximally, and the other was made of TMZF™ alloy and had a proximal coating of hydroxyapatite in addition to an arc-deposited titanium surface coating. Although we found extensions of radiopaque lines to the surface of coatings of seven grit-blasted stems whereas we found none in the case of the arc-deposited titanium stems, all hips showed excellent clinical and radiological outcomes as shown by radiographs and bone mineral density at the final follow-up, average 5.5 years postoperatively.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , , , , , , , , ,