Abstract

The purpose of this study was to determine the incidence, and the clinical and radiographic risk factors for significant subsidence of a cementless, modular tapered revision femoral stem. Femoral stem subsidence of at least 10 mm or subsidence requiring revision was considered significant subsidence. Ninety-seven patients (99 hips) were included with minimum radiographic follow-up of one year (mean 34 months; range, 12-91 months). The mean stem subsidence was 4.5 mm (range, 0-44 mm). Fourteen out of 99 (14.1%) stems had significant subsidence and 6 (6.1%) stems required revision due to subsidence. Patient weight greater than 80 kg (P = 0.04) and femoral stem press-fit distance of less than 2 cm (P < 0.01) were both independent risk factors for significant stem subsidence.