Article ID Journal Published Year Pages File Type
6209439 The Journal of Arthroplasty 2014 4 Pages PDF
Abstract

Semi-constrained implants provide stability in the setting of soft-tissue deficiency in revision total knee arthroplasty (TKA). This study evaluated our institution's long-term survival results with a semi-constrained implant used in the revision TKA setting. 234 semi-constrained revision total knee arthroplasties were performed in 209 patients. The average follow-up was 9 years. Forty repeat revisions were performed. 5-year survival was 91% and 10-year survival was 81%. Male gender significantly increased the risk of revision. At 10 years the average range of motion, pain level, and Knee Society score improved significantly (P < 0.001). Ninety percent of patients reported an improvement in their knee. The semi-constrained implant used in revision knee arthroplasty has acceptable implant survival and functional outcomes in the long-term follow-up period.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , ,