Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6214113 | International Journal of Pediatric Otorhinolaryngology | 2012 | 5 Pages |
ObjectiveExploratory research findings have suggested that otoacoustic emission (OAE) recordings may be predictive for infants at risk of sudden infant death syndrome (SIDS). The present study aimed to investigate whether an actual SIDS prevalence rate was comparable to OAE-determined rates for “at risk” status.MethodsPreviously collected OAE results from 521 infants in Hong Kong were used for analyses and OAE-determined “at risk” rate compared to the prevalence rate for SIDS in Hong Kong infants.ResultsResults indicated that the OAE-determined rates were very much greater than the actual prevalence of SIDS in Hong Kong.ConclusionThe use of OAE screening to identify infants at risk for SIDS is therefore not advisable, using present criteria, as false alarm rates would be very high and this may cause unnecessary parental anxiety and a considerable additional burden to the health care system.