Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
623807 | Desalination | 2013 | 9 Pages |
Abstract
⺠A model for mass extractions/injections in fixed-size HDH systems was developed. ⺠An increase in gained output ratio (GOR) of 10% was predicted. ⺠Better performance gains were found at higher extraction/injection temperatures. ⺠The optimal flow rate of the extraction/injection was ~ 40% of the feed flow rate. ⺠The sizing problem for the humidifier and dehumidifier is discussed.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Filtration and Separation
Authors
Gregory P. Thiel, Jacob A. Miller, Syed M. Zubair, John H. V,