Article ID Journal Published Year Pages File Type
6239384 Health Policy 2015 10 Pages PDF
Abstract

•MERIS pilot implemented in Greek health system.•Mandatory module: 35 adverse events in ICU.•Voluntary module: 510 reports on adverse events by citizens.

The economic crisis in Greece poses the necessity to resolve problems concerning both the spiralling cost and the quality assurance in the health system. The detection and the analysis of patient adverse events and medical errors are considered crucial elements of this course. The implementation of MERIS embodies a mandatory module, which adopts the trigger tool methodology for measuring adverse events and medical errors an intensive care unit [ICU] environment, and a voluntary one with web-based public reporting methodology. A pilot implementation of MERIS running in a public hospital identified 35 adverse events, with approx. 12 additional hospital days and an extra healthcare cost of €12,000 per adverse event or of about €312,000 per annum for ICU costs only. At the same time, the voluntary module unveiled 510 reports on adverse events submitted by citizens or patients. MERIS has been evaluated as a comprehensive and effective system; it succeeded in detecting the main factors that cause adverse events and discloses severe omissions of the Greek health system. MERIS may be incorporated and run efficiently nationally, adapted to the needs and peculiarities of each hospital or clinic.

Related Topics
Health Sciences Medicine and Dentistry Public Health and Health Policy
Authors
, , , ,