Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
623952 | Desalination | 2013 | 10 Pages |
Abstract
⺠Low water permeability of FO membranes determines low osmotic efficiency. ⺠If A is low, the active layer creates higher resistance than sublayer and interface. ⺠Non-uniform sublayer porosity affects the draw solute concentration profile. ⺠Membranes from a newly-synthesized CAP polymer have confirmed the above hypotheses.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Filtration and Separation
Authors
Jincai Su, Tai-Shung Chung, Bradley J. Helmer, Jos S. de Wit,