Article ID Journal Published Year Pages File Type
624006 Desalination 2013 6 Pages PDF
Abstract

•Methodology for accurate determination of permeate-side spacer permeability.•Typical effective lateral permeabilities of SWM spacers reported for the first time.•Spacer/fabric thickness variation with imposed pressure accurately measured.•Permeate-side permeabilities are essential for SWM design/performance simulation.

Reliable estimates of the effective lateral permeability (k) of permeate-side spacers of spiral wound membrane (SWM) elements are required in order to design them and simulate module and plant performance. Such permeability data are not available at present. A straightforward approach is recommended for determining k of spacers under modest pressure, which involves pressure drop measurements in a spacer-filled channel coupled with separate accurate data on the effect of normal pressure on spacer thickness. Application of this approach to typical spacers from commercial SWM modules shows that k is at the level of 2 to 3.5 × 10− 10 m2, for measured thickness 0.20 to 0.25 mm. The tested spacers exhibit modest compaction under pressure, with a tendency to approach asymptotically a minimum thickness at a pressure smaller than that prevailing in tightly wound membrane envelopes of commercial modules. Recommendations are also outlined regarding R & D directions on the selection of appropriate permeate spacers in the context of overall optimization of SWM module design and desalination process performance.

Related Topics
Physical Sciences and Engineering Chemical Engineering Filtration and Separation
Authors
, , ,