Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6245516 | Journal of Vascular and Interventional Radiology | 2016 | 6 Pages |
Abstract
The present study describes the technical feasibility of a combined-modality angiography/computed tomography (angio-CT)-assisted balloon dissection technique for bowel protection during renal cryoablation in six procedures in five patients. A retrospective review was performed to evaluate balloon dissection using the angio-CT system. Mean bowel-to-tumor distances before and after balloon dissection were 0.9 mm (range, 0-3 mm) and 13.0 mm (range, 11-17 mm), respectively. No bowel injury was observed during the mean follow-up period of 19 months (range, 7-44 mo). Our preliminary experience suggests that balloon dissection using the angio-CT system for bowel protection during renal cryoablation may be feasible and effective.
Related Topics
Health Sciences
Medicine and Dentistry
Radiology and Imaging
Authors
Miyuki MD, Yasuaki MD, Shunsuke MD, Koji MD, Keishi MD, Hiroaki MD, Shinichi MD,