Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6268815 | Journal of Neuroscience Methods | 2014 | 7 Pages |
Abstract
Electroencephalographic signals are commonly contaminated by eye artifacts, even if recorded under controlled conditions. The objective of this work was to quantitatively compare standard artifact removal methods (regression, filtered regression, Infomax, and second order blind identification (SOBI)) and two artifact identification approaches for independent component analysis (ICA) methods, i.e. ADJUST and correlation. To this end, eye artifacts were removed and the cleaned datasets were used for single trial classification of P300 (a type of event related potentials elicited using the oddball paradigm). Statistical analysis of the results confirms that the combination of Infomax and ADJUST provides a relatively better performance (0.6% improvement on average of all subject) while the combination of SOBI and correlation performs the worst. Low-pass filtering the data at lower cutoffs (here 4Â Hz) can also improve the classification accuracy. Without requiring any artifact reference channel, the combination of Infomax and ADJUST improves the classification performance more than the other methods for both examined filtering cutoffs, i.e., 4Â Hz and 25Â Hz.
Related Topics
Life Sciences
Neuroscience
Neuroscience (General)
Authors
Foad Ghaderi, Su Kyoung Kim, Elsa Andrea Kirchner,