Abstract
The results of the experimental study showed that under certain operating conditions, the system productivity decreases about 15% if double-pass solar air heater is not used and significant improvement on the productivity of the system is achieved by increasing the initial water temperature inside the storage tank. In addition, productivity of the system increases with increasing the feed water mass flow rate and quantity of water inside the storage tank. However, productivity of the system remains approximately the same when the air mass flow rate is increased. Moreover, increasing the cooling water mass flow rate results in the improvement on the productivity of the system investigated. Finally, results obtained from the present investigation were compared with the theoretical study and a good agreement between them is observed.
Related Topics
Physical Sciences and Engineering Chemical Engineering Filtration and Separation
Authors
, ,