In this study, continuous monitoring of VSCs from the headspace of an alternating aerobic and anoxic (AAA) activated sludge process via total reduced sulfur (TRS) analyzer was performed. There is clear pattern of the initial TRS peak immediately after the initiation of the aeration in the AAA system and TRS concentration begins to drop through the remaining air-on cycle. On the other hand, during the air-off period, TRS concentrations increase with time. In particular, a clear inflection point in the TRS profile could be observed after complete removal of nitrate during air-off, meaning more VSCs formation. Since the highest odor emission occurs after the initiation of aeration, the future control of exhausted air should only deal with air collected during the initial aeration period (e.g., 30Â min), a similar concept for the treatment of first flush in combined sewer overflow. In addition, application of a control scheme to initiate aeration immediately after denitrification is completed during air-off should be beneficial in reducing odor emission.