Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6330155 | Science of The Total Environment | 2014 | 9 Pages |
Abstract
The use of the Performance Reference Compound (PRC) is also discussed here. The impact of some environmental parameters and exposure setup on the transfer of pesticides in POCIS sorbent was studied: river flow rate, biofouling on membranes, sampler holding design and position in the stream. Results show a significant impact of river flow velocity on PRC desorption, especially for values higher than 4 cm·sâ 1. Some fouling was observed on the PES membrane which could potentially have an impact on molecule accumulation in the POCIS. Finally, the positioning of the sampler in the river did not have significant effects on pesticide accumulation, when perpendicular exposures were used (sampler positioning in front of the water flow). The POCIS with PRC correction seems to be a suitable tool for estimating time-weighted average (TWA) concentrations, for all the molecules except for one of the nine pesticides analyzed in these two French rivers.
Keywords
Related Topics
Life Sciences
Environmental Science
Environmental Chemistry
Authors
Sophie Lissalde, Nicolas Mazzella, Patrick Mazellier,