Article ID Journal Published Year Pages File Type
6342031 Atmospheric Environment 2012 8 Pages PDF
Abstract
► We measured particle penetration of smooth and rough crack experimentally. ► Fine particles concentration of 30 nm-500 nm were measured. ► At low pressure rough crack gives lower penetration than smooth crack. ► The results show that penetration is not sensitive to the roughness scales. ► A simple mathematical model accounting diffusion was developed for rough surfaces.
Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Atmospheric Science
Authors
, , , ,