Abstract
â¶ Pd-Au membranes were tested in synthetic WGS mixtures with up to 50Â ppm H2S. â¶ Higher gold content increases sulfur and carbon tolerance. â¶ Cold worked membranes are stable for hundreds of hours in H2S. â¶ Sputtered membranes corrode and lose selectivity when H2S is applied. â¶ Texturing and bulk crystal arrangements alter performance in mixed gases.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Filtration and Separation
Authors
Sabina K. Gade, Sarah J. DeVoss, Kent E. Coulter, Stephen N. Paglieri, Gökhan O. Alptekin, J. Douglas Way,