Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
652264 | Experimental Thermal and Fluid Science | 2012 | 8 Pages |
Abstract
⺠Mechanisms of temperature oscillation in LHP was confirmed at different heat loads. ⺠One reason of Temperature oscillation in LHP is insufficient driving force. ⺠Another reason is phase distribution in compensation chamber at different heat load. ⺠Operating stability is affected by phase distribution in the compensation chamber. ⺠High operating temperature can improve the operating stability of LHP.
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Xianfeng Zhang, Jiepeng Huo, Shuangfeng Wang,