Article ID Journal Published Year Pages File Type
654911 International Communications in Heat and Mass Transfer 2006 10 Pages PDF
Abstract

The effects of V-nozzle inserts on heat transfer and friction characteristics in a uniform heat flux tube are experimentally studied. Three different pitch ratios (PR) of V-nozzle arrangements in the test tube are introduced with PR = 2.0, 4.0, and 7.0, in each run. The results of experimental investigations of heat transfer, friction characteristic and enhancement efficiency are presented. It is found that using the V-nozzle can help to increase considerably the heat transfer rate at about 270% over the plain tube. A maximum gain of 1.19 on enhancement efficiency is obtained for the smallest pitch ratio used, PR = 2.0. This indicates that the effect of the reverse/re-circulation flows can improve the heat transfer rate in the tube. In addition, correlations from the results are presented.

Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, ,