Abstract
In this work, both a multi-droplet size model and a size distribution model are implemented. The multi-droplet size model is used for validation and results are in line with findings from the mono-disperse model by (Majeed et al., 2017b; Majeed and Svendsen, 2018a). Droplet distribution model results are compared with experimental data from Toshiba (Fujita, 2017) and reasonable agreement is found. The development of inlet droplet distributions through an absorber and water-wash system is modelled for several flue gas sources. It is found that the outlet distribution mean size increases with inlet gas CO2 concentration. Similarly, the outlet mean droplet size decreases and the size distribution width increases with incoming droplet number concentration.