Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
659566 | International Journal of Heat and Mass Transfer | 2010 | 8 Pages |
A two-dimensional finite element model describing the performance of parallel-plate regenerators with arbitrary channel width distributions has been developed in order to investigate the effect of non-uniform plate spacing on the performance of regenerators. Results for a series of hypothetical plate spacing distributions are presented in order to understand the impact of spacing non-uniformity. Simulations of more realistic distributions where the plate spacings follow normal distributions are then discussed in order to describe the deviation of the performance of a regenerator relative to one with uniform spacing as a function of the standard deviation of the plate distribution. It has been shown that the most significant reduction in performance occurs when a volume of fluid between 100% and 200% of the regenerator void volume is displaced in a single blow.