Abstract
All-metallic sandwich panels with prismatic cores are being currently investigated for combined structural and active cooling performance. We present a new approach to active cooling performance, and use it to optimize the panel geometry for four different systems: aluminum-air, aluminum-water, aluminum-gasoline and titanium-gasoline. The results show that some geometric parameters can be fixed without much detriment in thermal performance. Moreover, while optimal core densities are typically 25–50%, near-optimal results can be obtained with densities as low as 10%. These findings provide considerable geometric flexibility when attempting combined thermal and structural optimization.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
L. Valdevit, A. Pantano, H.A. Stone, A.G. Evans,