Article ID Journal Published Year Pages File Type
6644973 Fuel 2012 7 Pages PDF
Abstract
► Impacts of boiler parameters on Hg emissions were investigated at a coal-fired power plant. ► The plant was burning low chlorine (Cl) PRB coal. ► The Hg reduction at the stack was lower than the power plants which burn high Cl coals. ► OHM and mercury SCEM measurements showed excellent agreement. ► Boiler modifications resulted in 34.5% reduction in HgT emissions in the stack.
Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Engineering (General)