Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6661676 | Journal of Electroanalytical Chemistry | 2018 | 8 Pages |
Abstract
A simple and sensitive sensor of poly(3,4-ethylenedioxythiophene)/reduced graphene oxide/manganese dioxide modified glassy carbon electrode (PrGO/MnO2) was fabricated via cyclic voltammetry (CV) for simultaneous detection of uric acid (UA), dopamine (DA) and ascorbic acid (AA). The PrGO/MnO2 composite film possessed excellent electrocatalytic rate and high selectivity towards the oxidation of UA, DA and AA in 0.1â¯M PBS (pHâ¯6.0). The peak potential separation (âEp) of AA-DA, AA-UA and DA-UA were 166, 312 and 146â¯mV, respectively. The detection limits of 1.00, 0.02 and 0.05â¯Î¼M with a linear response of 1-800, 0.03-45 and 0.3-80â¯Î¼M were obtained for AA, DA and UA, respectively. This sensor also showed an excellent stability (reproducibility and repeatability).
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Chemical Engineering (General)
Authors
Nurulkhalilah Tukimin, Jaafar Abdullah, Yusran Sulaiman,