Article ID Journal Published Year Pages File Type
668063 International Journal of Thermal Sciences 2015 10 Pages PDF
Abstract
Heat transfer, pressure drop and effectiveness in a double pipe heat exchanger made of corrugated outer and inner tubes have been experimentally investigated in this paper. Both of the inner and outer tubes were corrugated by means of a special machine. New various arrangements of convex and concave corrugated tube were investigated. Heat transfer coefficient was determined using Wilson plots. Hot water (inner tube) and cold water (outer tube) inlet temperatures were maintained at around 40 °C and 8 °C respectively. Experiments were performed over the Reynolds number range of 3500-18,000, based on the hydraulic diameter of the annular space between the two tubes. Hot water Reynolds number was kept constant at around 5500. Findings indicated that the outer tube corrugations and arrangement type of corrugated tubes have significant effect on thermal and frictional characteristics. Maximum effectiveness was obtained for heat exchanger made of concave corrugated outer tube and convex corrugated inner tube.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , ,