Abstract
► Effect of adiabatic spacing size between heat sources on heat transfer is studied. ► Hot spot temperature is reduced by 11% for two heat sources with uniform heat flux. ► For two heat sources with uniform temperature, heat transfer is enhanced by 7.7%.