Abstract
During the development of this work, the authors have paid careful attention to the verification of experimental data. Such verification consists of performing energy and mass balances in the fluid film side. Important discrepancies were found in our experimental data. Therefore, an extensive study was carried out in order to find the source of such errors. The conclusion is that there is a drag of LiBr solution in the water vapour which increases with the Re number. This mist flow cannot be measured experimentally, but can be evaluated in an indirect way. The mathematical models have been adapted in order to consider the influence of mist flow. On the other hand, in the literature there are not many experimental works related to falling film absorbers which expose enough information to verify the reliability of their experimental data.
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
E. GarcÃa-Rivera, J. Castro, J. Farnós, A. Oliva,