| Article ID | Journal | Published Year | Pages | File Type | 
|---|---|---|---|---|
| 6707024 | Composite Structures | 2015 | 12 Pages | 
Abstract
												Experimental results show that both corroded and control deep beams repaired only in bending failed due to shear mode of failure (diagonal tension failure), while corroded and control beams repaired in both bending and shear failed due to concrete crushing. The test results also showed that the corrosion of both longitudinal and transversal reinforcement hardly modified the mechanical response of deep beams.
											Keywords
												
											Related Topics
												
													Physical Sciences and Engineering
													Engineering
													Civil and Structural Engineering
												
											Authors
												Belal Almassri, Amjad Kreit, Firas Al Mahmoud, Raoul Francois, 
											