Article ID Journal Published Year Pages File Type
6711959 Construction and Building Materials 2018 9 Pages PDF
Abstract
This research aimed to study the minimum requirements of shear reinforcement for ultra high performance fiber reinforced concrete deep beams. The experimental results showed that increasing the provided vertical web reinforcement ratio has slight effect on the diagonal cracking strength and the ultimate shear strength. The maximum spacing between the vertical web reinforcement required by ACI 318-2014 for reinforced concrete beams (d/5) is not suitable for ultra-high performance fiber reinforced concrete deep beams, while for the EC-2 (2b) and that required by the Egyptian code ECP-203-2017 (200 mm) is applicable. The recommendations of AFGC-2013 and KCI-2012 are safe and conservative more than that required by ACI 318-2014.
Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , ,