Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
672617 | Particuology | 2008 | 5 Pages |
Abstract
The mass concentration and size distribution of aerosols in Tokaimura were investigated using a high-volume and a low-volume Andersen sampler. A difference was found using the two samplers: the concentration of total aerosols determined with the high-volume sampler is smaller than that of the low-volume sampler by 70–90% throughout the year. Compared to the high-volume sampler, low-volume sampler gave lower concentration for aerosols >7 μm, higher concentration for aerosols of 3.3–7.0 μm and <1.1 μm, though similar results for aerosols of 1.1–3.3 μm. The low-volume sampler was found to have better separation efficiency and higher accuracy.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Fengfu Fu, Nobuo Shinohaya, Mitsuo Ito, Xueqin Xu, Mincong Shen, Liangjun Xu,