Abstract
The presence of the PS-TIM structure significantly affects the thermal and optical performance of the window system in which it is employed. This presents a further significant challenge when trying to predict its performance using dynamic building simulation approaches. Using a typical small office as a case study subject to varying climatic conditions, we investigate the thermal and optical behaviour of a range of PS-TIMs with respect to their daylight and energy performance. We find that when compared to a conventional double glazed system, the application of PS-TIMs can result in a more visually comfortable and uniformly lit environment, which might be desired in an office space, and, in the specific case of the small office under test, can result in a reduction in energy consumption of up to 35.8%. Furthermore, having explored the performance of the system in response to varying climatic conditions, we also present some advice as to how architects and engineers might apply PS-TIMs to window systems or glazed façades.
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
Yanyi Sun, Runqi Liang, Yupeng Wu, Robin Wilson, Peter Rutherford,