Article ID Journal Published Year Pages File Type
6731308 Energy and Buildings 2015 34 Pages PDF
Abstract
In mild climate areas, building glazings are required to perform as solar control systems with a low solar factor in order to avoid overheating. However, g-value is frequently unavailable in the data sheet of the STPV elements, making it difficult to design the optimal building solution. In the present work, an indoor testing facility to analyze the solar factor of STPV elements has been further developed and validated. The operating principles of the calorimetric system as well as the experimental data obtained in the validation stage are presented. Results show that the system accuracy and sensitivity are fully adequate to perform detailed analyses of the solar factor of STPV glazings. Furthermore, g-value variations with the transparency degree have been analyzed over different electrical operating points.
Related Topics
Physical Sciences and Engineering Energy Renewable Energy, Sustainability and the Environment
Authors
, , , , ,