Abstract
This paper demonstrates an optimal household appliance scheduling problem with a battery as an energy storage system under time of use electricity tariff. Power consumption measurements of individual appliances considered were performed and demand profiles were obtained. In this work, a mixed integer nonlinear programming mathematical model with more practical operation constraints for appliance and battery scheduling is formulated and solved. The simulation results show effectiveness of the algorithm in that by optimally scheduling appliances and battery, cost saving, peak shaving and valley filling are achieved through load shifting. The energy cost saving that might be beneficial to consumers; and peak shaving and valley filling, which are of great importance to the utility. It is found that consideration of appliance coordination yields smaller cost saving because of interdependent operation. Without the battery and coordination, a cost saving of 22% and peak reduction from 10.355Â kW to 8.405Â kW are realized. Consideration of appliance coordination gives a further cost saving of 1% and a relatively smaller peak reduction to 8.30Â kW. The battery bank system promotes peak shaving and valley filling and a further cost saving of about 6% and peak reduction to 5.175Â kW. Sensitivity analysis, however, reveals that the energy cost saving is sensitive to consumer's willingness to pay.
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
Ditiro Setlhaolo, Xiaohua Xia,