Abstract
In this paper, a 1:5 scaled tower model for a typical 220â¯kV single-circuit power transmission tower with hybrid slab foundation has been designed and tested. The scaled tower model was tested under the movement of horizontal ground surface stretching with normal working loading conditions. One of the main objectives of this research is to investigate the stability of the power transmission tower subjected to horizontal ground movement by using hybrid slab foundation. The deformations of the tested tower model and stresses and strains within the different structural members of the tower and the reinforced concrete slab of the foundation have been fully measured. A large mount comprehensive test data has been generated. The research clearly indicated that compared to the isolated tower leg's foundation the proposed hybrid slab foundation has very good resistance, in terms of truss members' deformations and stresses, to the ground movement.
Related Topics
Physical Sciences and Engineering
Earth and Planetary Sciences
Geotechnical Engineering and Engineering Geology
Authors
Guanglin Yuan, Biao Yang, Zhaohui Huang, Xiaozhe Tan,