Article ID Journal Published Year Pages File Type
6738246 Engineering Structures 2018 12 Pages PDF
Abstract
The paper is concerned with the development of a failure criterion capable of accurately predicting the shear capacity of reinforced concrete T-beams while correctly accounting for the beneficial effect of the increase of the compressive zone due to the presence of flanges. The development of the subject criterion is based on an alternative design method (the compressive force path method) that leads to predictions of reinforced concrete structural behaviour and design solutions considerably different compared to those of the current design codes without however compromising structural performance requirements (mainly associated with ductility and strength). The validity of the proposed failure criterion is verified through a comparative study of the calculated values with their experimentally-established counterparts obtained from an extensive literature survey. Through this comparative study it is demonstrated that the predictions of the proposed criterion provide a closer fit to the available experimental data than their counterparts obtained from the design codes considered.
Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Geotechnical Engineering and Engineering Geology
Authors
, ,